Energy-efficient building design is becoming a central urban infrastructure question in India, where buildings account for more than 30 per cent of total electricity consumption, according to the Bureau of Energy Efficiency. The figure shifts attention away from the electricity bill at the end of a building’s life and towards the architectural, planning and engineering decisions made before construction begins.
The conventional conversation about efficient buildings often starts with equipment: air-conditioning systems, smart controls, building management systems and energy-efficient lighting. These technologies can reduce waste, but they operate after a building’s basic demand has already been shaped. Orientation, façade design, window placement, shading, space planning and the distribution of cooling and lighting loads determine how much energy a building needs in the first place.
That distinction is important for Indian cities. As more homes, offices, retail spaces and mixed-use developments are built, electricity demand is not only a question of how efficiently individual appliances operate. It is also a question of whether buildings are designed to prevent avoidable heat gain, use daylight effectively and match energy consumption to actual occupancy. A building that requires less cooling because less heat enters its interiors has a different energy profile from one that depends on mechanical systems to correct design weaknesses.
Koheli J Puri, founder and managing director of Studio XP, told NDTV that experiences in Japan and Dubai shaped her view of the relationship between comfort and consumption. She contrasted everyday systems in Japan with heavily air-conditioned premium interiors in Dubai, including spaces maintained at 20 degrees Celsius despite high outdoor temperatures. Her question was whether a premium environment must necessarily consume more resources.
Puri’s argument, as reported by NDTV, is that sustainable luxury should not mean reducing comfort. Instead, it should mean designing spaces that provide comfort with lower energy demand. This places the issue at the design stage, where decisions can influence the building’s performance for decades and are generally easier to change than systems in an occupied structure.
The building envelope is one of the clearest examples. Large west-facing windows can increase afternoon heat gain, placing additional pressure on air-conditioning systems. The article identifies glazing, external shading and careful window placement as ways to preserve natural light while limiting unwanted heat. Puri said that reducing the heat entering a building lowers the cooling load before mechanical systems need to operate.
This is a shift from treating air-conditioning as the primary answer to heat. Once heat has entered an interior, it must be removed, and that process consumes electricity. Shading and façade decisions cannot eliminate the need for cooling in every situation, but they can influence the scale of the demand that cooling systems must meet. The design question therefore precedes the equipment question.
Space planning creates a second layer of energy demand. In a mixed-use development, retail areas may remain active late into the evening, while residential common areas follow different occupancy patterns. If lighting and cooling are operated uniformly across the entire development, areas with fewer occupants may continue consuming energy at levels intended for busier spaces.
Zoning systems around actual use can make energy consumption more responsive. The underlying principle is straightforward: areas should receive the lighting and cooling they need rather than being managed as though every part of a development has the same activity, schedule or occupancy. This requires coordination between architecture, building services and operations rather than treating energy management as a facility-management task added after completion.
Technology becomes more useful when it responds to these real conditions. Occupancy changes, temperatures fluctuate and equipment requires maintenance. Building management systems can use operational data to identify inefficiencies, adjust settings and respond to changing requirements. However, technology does not replace the design process. It manages demand after the building has been configured; it cannot fully compensate for every inefficient orientation, façade or spatial arrangement.
Puri cited One Bangkok, a 41-acre mixed-use development, as an example of intelligent infrastructure supporting building performance. According to her account, the development has more than 250,000 sensors and delivers around 17,000 megawatt-hours of electricity savings per year. She also said that its wider sustainability infrastructure, including district cooling, saves around 9,000 tonnes of carbon dioxide.
These figures are presented in the supplied report as statements by Puri and are not independently assessed within the material. They nevertheless illustrate the scale at which digital systems and shared infrastructure can operate in a large mixed-use development. Sensors can provide information about how buildings are being used, while district cooling can centralise part of the cooling system rather than leaving every building to manage the same requirement independently.
The example also shows why energy performance is not controlled by a single discipline. A sensor network is an operational and technology intervention. District cooling is an infrastructure decision. Façade design and window placement belong to architecture and building engineering. Zoning relates to planning and services coordination. The building’s energy outcome is created by the interaction of all these choices.
Energy modelling provides a way to test those choices before construction. Project teams can compare façade options, estimate cooling loads and coordinate architectural decisions with building services. The supplied report notes that identifying an inefficient design on paper is generally easier and less expensive than correcting it after construction. This makes modelling a project-planning tool, not merely a technical exercise.
The timing matters because many high-impact decisions become difficult to reverse once a building is occupied. Changing a control system may be possible after completion, but altering the orientation, window proportions or core façade strategy can be considerably more disruptive. Treating energy performance as an operational issue alone can therefore leave developers trying to repair a demand pattern that was established during design.
India already has a policy framework for improving the performance of eligible commercial buildings. The Bureau of Energy Efficiency’s Energy Conservation Building Code provides standards and a benchmark for energy performance. The supplied material does not detail the code’s enforcement arrangements, compliance outcomes or coverage across different building types, so those questions remain outside what can be established here.
The existence of a code also does not by itself establish how a building will perform in everyday use. Compliance at the design or construction stage and actual operational performance are related but distinct questions. Buildings experience changing occupancy, maintenance conditions and user behaviour. A development may therefore need both a sound initial design and systems capable of monitoring and adjusting performance after handover.
The available numbers point to the scale of the challenge and the possible range of interventions. The BEE estimate places building consumption at more than 30 per cent of India’s total electricity use. The One Bangkok example cited by Puri combines 250,000 sensors, approximately 17,000 MWh in annual electricity savings and about 9,000 tonnes of carbon dioxide savings through wider sustainability infrastructure. The comparison should not be treated as a national benchmark: the figures relate to one 41-acre mixed-use development and are attributed to an individual quoted in the report.
What the evidence does establish is a sequence for thinking about building energy. First, reduce avoidable demand through orientation, façade design, shading, glazing, window placement and space planning. Second, use building systems and operational data to manage the demand that remains. Third, assess performance against the building’s intended use rather than assuming that design-stage compliance alone guarantees efficient operation.
This sequence has implications for developers, architects, engineers and municipal and building authorities. Developers make decisions about cost, programme and specifications. Architects shape the building envelope and spatial arrangement. Engineers size and coordinate cooling, lighting and control systems. Facility managers operate the completed asset. Energy performance can weaken when these responsibilities are treated as separate stages rather than as a connected process.
The larger urban question is whether India’s growing building stock will lock cities into high electricity demand or whether demand can be reduced through better design before new capacity is required. Buildings are long-lived infrastructure. Their windows, façades, cooling systems and operating patterns influence not only private electricity bills but also the load placed on urban power networks.
The supplied evidence supports a clear conclusion: energy efficiency begins before a building is occupied. Technology, sensors and building management systems can improve performance, but they work best when the building has already been designed to avoid unnecessary heat and consumption. The next issues to monitor are how energy codes are implemented, how performance is measured after handover and whether design-stage efficiency becomes a routine requirement rather than a premium feature.