India’s building energy problem is often treated as an equipment problem: install efficient air-conditioners, automate lighting and deploy smarter building management systems. But the more consequential decisions may be made much earlier, when a project’s orientation, façade, glazing, layout and cooling strategy are still being designed. That is the central argument emerging from a discussion on how building energy efficiency can reduce electricity demand before a building becomes operational.
Buildings account for more than 30 per cent of India’s total electricity consumption, according to the Bureau of Energy Efficiency, as cited by NDTV Business. That figure places the built environment at the centre of the country’s energy challenge. It also changes the way efficiency should be understood. A building that receives excessive afternoon heat through a poorly designed façade may require more cooling throughout its life. A mixed-use development with undifferentiated lighting and air-conditioning zones may consume electricity in areas that are vacant or lightly used. Technology can manage these inefficiencies, but design determines how much inefficiency exists in the first place.
This distinction matters because buildings lock in many of their energy requirements long before tenants, facility managers or occupants can influence daily operations. Once a tower has been built with extensive west-facing glazing, limited shading or an inefficient spatial arrangement, correcting the resulting heat gain may require expensive retrofits or permanent dependence on mechanical cooling. Energy efficiency therefore begins not with the building management system, but with the decisions taken by the architect, developer, services consultant and project team during the design stage.
Koheli J Puri, Founder and Managing Director of Studio XP, told NDTV Business that her experiences in Japan and Dubai prompted her to examine the relationship between comfort, luxury and resource consumption. She described encountering spaces that used extensive air-conditioning, including interiors maintained at 20 degrees Celsius despite high outdoor temperatures. Her broader question was whether a premium space must consume more resources to provide comfort, or whether comfort can be designed with lower energy demand.
That question is particularly relevant to India’s expanding urban building stock. Commercial districts, residential complexes, retail developments and mixed-use projects increasingly use large glazed surfaces, sealed interiors and mechanically conditioned spaces. These features can support a particular visual language or operational model, but they can also increase exposure to solar heat and raise cooling requirements. The design challenge is not simply to remove air-conditioning from buildings. It is to reduce the amount of heat and demand that air-conditioning must manage.
Building orientation and façade design are among the earliest levers available to project teams. Large west-facing windows can allow substantial afternoon heat gain. Appropriate glazing, external shading and carefully considered window placement can preserve daylight while limiting unwanted heat entering the building. This is a basic but important shift in approach: instead of allowing heat to enter and then using electricity to remove it, the building can be designed to moderate that heat at the envelope.
The same principle applies to internal planning. In a mixed-use development, retail areas may remain active late into the evening, while residential common areas, offices or other facilities may follow different occupancy patterns. If lighting and cooling are controlled uniformly across the entire development, electricity may be consumed in spaces that are unoccupied or require less conditioning. Zoning based on actual use allows systems to respond to the way a building functions rather than treating every area as equally active.
This is where the relationship between passive design and operational technology becomes important. Design reduces avoidable demand; digital systems help manage the remaining demand as conditions change. Occupancy levels vary, outdoor temperatures fluctuate and equipment performance can deteriorate over time. Building management systems can use operational data to adjust settings, identify inefficiencies and respond to changing requirements. Such systems are most effective when they are managing a building that has already been designed with reasonable energy performance in mind.
Puri cited One Bangkok, a 41-acre mixed-use development, as an example of how intelligent infrastructure can be used at scale. According to her account, the development has more than 250,000 sensors and delivers around 17,000 megawatt-hours of electricity savings per year. Its wider sustainability infrastructure, including district cooling, was also cited as saving approximately 9,000 tonnes of carbon dioxide. These figures were presented as part of her experience of the project and illustrate the potential scale of data-enabled building operations, although they do not establish that the same performance can be replicated across all Indian developments.
The example also shows why technology should not be treated as a substitute for design discipline. Sensors can reveal occupancy, temperatures and equipment conditions, but they cannot change the basic orientation of a completed building or eliminate heat entering through an unsuitable façade. Digital infrastructure can fine-tune performance and identify waste. It cannot always reverse decisions that were embedded in the structure during planning and construction.
Energy modelling provides a mechanism for testing those decisions before they become physical. Project teams can compare façade options, estimate cooling loads and coordinate architectural choices with building services before construction begins. An inefficient option identified on paper can generally be modified more easily than a completed building with excessive energy demand. This makes modelling not only an environmental tool but also a project-planning tool, because it brings architectural, engineering and operational questions into the same decision process.
The Bureau of Energy Efficiency’s Energy Conservation Building Code provides a framework for improving the energy performance of eligible commercial buildings. The code establishes an important benchmark for design and construction, but compliance alone does not fully answer how a building will perform in everyday use. Actual performance depends on how systems are commissioned, how controls are operated, how maintenance is carried out and whether occupants use spaces in the way assumed during design.
That gap between designed performance and operational performance is a governance issue as much as a technical one. Developers make early decisions, architects shape the building envelope and spatial plan, engineers specify building services, contractors execute the design and facility managers operate the completed asset. If energy performance is considered only at the final approval or equipment-selection stage, responsibility becomes fragmented. If it is built into the project from the outset, the different actors can be assessed against a clearer performance objective.
The electricity implications extend beyond individual buildings. When a large number of urban buildings rely on mechanical cooling to compensate for avoidable heat gain, demand is aggregated across the electricity system. The design of a façade or the zoning of a mixed-use development may appear to be a project-level decision, but repeated across a city, such decisions influence peak demand, operating costs and the infrastructure required to supply power. The supplied evidence does not quantify that city-level effect, but the scale of India’s building electricity consumption makes the connection difficult to ignore.
There is also a practical affordability question. Energy-efficient design is often discussed through the language of premium developments and advanced technology, yet the underlying measures are not limited to high-end projects. Orientation, shading, window placement, zoning and early-stage energy modelling are design and planning decisions. Their feasibility will vary by site, building type and project budget, but the principle of reducing demand before adding equipment can apply across different segments of the built environment.
For occupants, energy performance is experienced through more than the monthly electricity bill. It affects thermal comfort, indoor conditions and the reliability of building systems. In commercial and mixed-use properties, it also influences common-area operating costs and the management of shared infrastructure. The benefits of better design may therefore be distributed among developers, owners, tenants and facility managers, while the costs of poor design can persist through the life of the building.
The larger urban question is whether India’s construction process is treating energy as an operational afterthought or as a design parameter. The evidence cited by NDTV Business supports a clear sequence: reduce avoidable demand through orientation and envelope design, match lighting and cooling to actual use, then use sensors and building management systems to manage changing conditions. Energy codes can provide a baseline, while modelling and commissioning can help determine whether the completed building performs as intended.
What remains less established in the supplied material is how consistently these practices are being adopted across India’s building stock, how their upfront costs compare across project categories and whether operational savings are being measured after occupation. Those questions will determine whether building energy efficiency remains a feature of selected developments or becomes a routine part of urban construction. The immediate lesson, however, is clear: the most durable electricity saving may come from requiring a building to do less work before technology is asked to make it smarter.