HomeAnalysisIndoor Air Pollution Runs Higher in Many South Delhi Homes

Indoor Air Pollution Runs Higher in Many South Delhi Homes

Indoor air pollution was higher than outdoor pollution in all 24 south Delhi homes assessed in a study, with poorly ventilated houses recording particularly elevated concentrations of fine particulate matter and PM10.

The research found that indoor PM2.5 concentrations in poorly ventilated homes averaged 119.17 micrograms per cubic metre, compared with 79.34 micrograms per cubic metre outdoors — about 50 per cent higher. PM2.5 refers to fine particles small enough to enter deep into the respiratory system.

In homes classified as well ventilated, indoor PM2.5 averaged 77.34 micrograms per cubic metre, against 56.14 micrograms per cubic metre outdoors. Although the levels were lower than in poorly ventilated homes, indoor concentrations were still around 38 per cent higher than outdoor readings.

The same pattern was recorded for PM10. Poorly ventilated homes had average indoor PM10 concentrations of 138.63 micrograms per cubic metre, compared with 91.19 micrograms per cubic metre outdoors. In well-ventilated houses, indoor PM10 averaged 89.51 micrograms per cubic metre, while outdoor levels averaged 64.81 micrograms per cubic metre.

Across all 24 homes, indoor PM2.5 averaged 98.25 micrograms per cubic metre, about 45 per cent above the outdoor average of 67.74 micrograms per cubic metre. The corresponding indoor PM10 average was 114.07 micrograms per cubic metre, around 46 per cent higher than the outdoor average of 78 micrograms per cubic metre.

The study covered homes in Shaheen Bagh, Jasola Vihar, Batla House and Okhla Vihar. Researchers monitored indoor air in kitchens and outdoor air on balconies between February and April 2023. Measurements were taken during the daytime for eight hours a day over three consecutive days in each house. Night-time monitoring was not conducted because of privacy concerns.

According to the report, homes were classified as well ventilated or poorly ventilated based on whether functional kitchen chimneys or exhaust fans were operating during monitoring. The research team included scholars from Jamia Millia Islamia in New Delhi, Jazan University in Saudi Arabia and Baba Ghulam Shah Badshah University in Rajouri, Jammu and Kashmir. The study was published in the journal Discover Environment in 2025.

The findings are significant for residential design because they show that being indoors does not automatically provide protection from polluted air. Ventilation equipment, kitchen layout, maintenance of exhaust systems and the management of indoor emission sources can influence the air residents breathe inside their homes.

The researchers attributed the higher indoor concentrations to a combination of indoor activities, inadequate ventilation and the entry of outdoor pollutants. Cooking, cleaning, smoking and burning incense sticks were identified as possible contributors. However, the study did not quantify how much each source contributed to the measured pollution.

That limitation is important when interpreting the findings. The sample covered only 24 homes in four neighbourhoods, and monitoring was limited to daytime kitchen readings and balcony measurements. The results therefore indicate a strong association between ventilation conditions and indoor particulate levels in the homes studied, but they do not establish a citywide average or separate the effects of individual pollution sources.

Even with those limitations, the comparison between ventilation conditions provides a practical built-environment lesson. Poorly ventilated homes recorded indoor PM2.5 levels about 54 per cent higher than well-ventilated homes, while their indoor PM10 levels were around 55 per cent higher. The researchers said improving ventilation practices, maintaining exhaust systems and reducing indoor pollution sources could help improve air quality inside homes.

For residents, the findings point to the importance of functioning kitchen chimneys and exhaust fans, particularly during cooking and other activities that generate particles. For housing design and maintenance, they underline that ventilation systems need to be provided, used and kept operational rather than treated as optional fittings. The study also highlights the need for further monitoring across different building types, seasons, rooms and times of day before broader conclusions are drawn.


RELATED ARTICLES

Most Popular

Latest News